Two new Micro-Invasive Glaucoma Surgery (MIGS) implants gained FDA approval in 2016: the Alcon CyPass Micro-Stent® and the Allergan XEN® Gel Implant. Of these, only the CyPass Micro-Stent® offers a bleb-free method of reducing intraocular pressure (IOP). The CyPass...
MicroPulse® P3 Glaucoma Device (MP3) Innovative Cyclophotocoagulation with MicroPulse Technology Powered by the NEW CYCLO G6™ Glaucoma Laser System | Source: iridex.com One-Year Results of Micropulse Trans-scleral Cyclophotocoagulation for the Treatment of Glaucoma...
Most glaucoma surgeons agree that Minimally Invasive Glaucoma Surgery (MIGS) Procedures are “gentler” than trabeculectomy or glaucoma drainage devices. MIGS Procedures are faster, done through very small corneal incisions, and have fewer risks. However,...
Micropulse® Laser Trans-Scleral Cyclophotocoagulation (MP-TSCPC) using the Iridex P3 probe (MP3) was a hot topic at the American Glaucoma Society (AGS) 2017 Annual Meeting in San Diego, CA (March 2-5). Multiple posters were presented sharing the results of using this...
Dr. Mahmoud A. Khaimi presented 12-month data on the benefit and risks of Ab-Interno Canaloplasty (ABiC) with or without cataract surgery at the recent American Glaucoma Society (AGS) 2017 Annual Meeting in San Diego, CA (March 2-5). This study included 86 eyes of...
Research poster from the American Glaucoma Society Source: IRIDEX – Great work by Dr. Murray Johnstone | Facebook [Internet]. Facebook.com. 2017 [cited 2017 Mar 14]. Available from: https://www.facebook.com/IRIDEX/ How Micropulse® P3 Cyclophotocoagulation Works...
Who Will Likely Benefit from the Stegmann Canal Expander®? Most anyone who is a candidate for canaloplasty should also benefit from placement of the Stegmann Canal Expander®. At the time of this writing, however, only those outside of the USA can do so as the FDA has...
When the results of this study are compared to the results of prior long-term studies of Canaloplasty glaucoma surgery, use of the Stegmann Canal Expander® appears to provide an additional 3mmHg of IOP lowering effect.2 Source: Canal Expander | Canal Expander...
The risks of canaloplasty with the Stegmann Canal Expander® were shown to be quite similar to Canaloplasty without the Stegmann Canal Expander®. Just over one quarter of patients experienced a hyphema (blood in the front part of the eye). However, this is viewed by...
Source: Canal Expander | Canal Expander [Internet]. Canalexpander.com. 2017 [cited 2017 Mar 18]. Available from: http://www.canalexpander.com/canal-expander/ Two-Year Results The results of a study evaluating canaloplasty with the Stegmann Canal Expander® have...